Add to Cart
Microwave CVD, Intelligent / Smart Tube Furnace, Multi Phase Reaction, High Power
HY-ZG3012E uses resistance wire as electric heating source and microwave absoring material silicon carbide embedded within the insulation as microwave heating source.
HY-ZG3012E uses a separate work tube to protecting the heating samples from damage or pollution.
Users can choose working tube in different diameter, i.e 60 millimeter or 80 millimeter.
HY-ZG3012E uses high precision cooling water machine to cool down magnetrons and prevent magnetrons and the whole furnace from over temperature or over heating.
HY-ZG3012E can be used for multi phase reaction, multi phase synthesis with high capacity.
| Parameters | HY-ZG3012E | |
| Power | Voltage | 380V±10V 50Hz |
| Rated Power | 7KW | |
| Electrical Heating Power | 3KW | |
| Microwave System |
Microwave Output Power | 0.10~2.80KW continuously adjustable |
| Microwave Frequency | 2.45GHz | |
| Microwave Leakage Prevention | microwave leakage intensity <2mW/cm2 | |
| Thermal Insulation System |
Tmax | 1200°C |
| Working Temperature | 0~1150°C | |
| Heating Space (diameter×width) |
Φ60×130mm | |
| Temperature Control System |
Temperature Measurement Method |
thermocouple |
| Temperature Measurement Range |
0°C~1300°C | |
| Temperature Control Precision |
±0.1% | |
| Control System |
Auto, Manual and Isothermal Controlling Mode, PLC+Touch Screen |
40 segments of programmable technical parameters, data storage and export, real-time curve data display, dynamic data display |
| Atmosphere System | Static Ultimate Vacuum Degree |
≤100Pa |
| Atmosphere Range | quick pre-vacuum pumping, capalble of oxidizing gas, inert gas, weak reducing gas etc. |
|
| Safety System | Magnetron Alarm | over temperature alarm |
| Furnace Door Protection Alarm | furnace door shutdown sensor | |
| Overall Dimension |
Furnace Body(L×W×H) | ca. 530×430×380mm |
| Rack(L×W×H) | ca. 900×500×700mm | |